5 Simple Techniques For ATS Socomec

Protection and dependability ATyS p have the two electrical and mechanical interlocks for maximum security. The 0 position provides electrical protection disconnection and will allow TSE lockout According to IEC60947-3.

Fast commissioning On Preliminary electric power up, the ATyS C65’s intelligent wizard will information the operator in the commissioning method.

A lot more strong The current style involves metallic mounting legs through the whole ATyS selection, improving upon the overall robustness from the switches.

ATyS C55 is an entire ATSE controller that may be utilized to pilot a remotely operated transfer swap of any engineering: motorised switches (e.g. ATyS r, ATyS S or ATyS d M), circuit breakers or contactors.

Risk to set periodic genset startup Chance to set periodic genset startup ATyS p switches offer more functions for routine maintenance. They consist of a programmable genset commencing perform which permits the starting up dates and working instances for being configured.

Watchdog relay to check product or service availability ATyS r goods are Outfitted which has a Watchdog relay which continuously screens your product or service, thus securing the installation.

These are meant to be used in small voltage electric power provide units the place a brief interruption with the load supply is suitable in the course of transfer.

For additional security, a tripping function is on the market, making it possible for likely to 0 posture with no external electric power provide in the event of 2 resources blackoutand a permanent standing checking and also interaction attribute.

Much more robust The updated design includes metallic mounting legs through the overall ATyS array, increasing the general robustness on the switches. Furthermore, it makes it possible for A simpler and difficulty-totally free mounting of the switches with a back again plate check here with preassembled screws.

Let us kickstart your new college year that has a burst of enthusiasm and countless choices! Prepare for an fascinating journey of learning and expansion ahead!

Recording of situations ATyS p switches permit efficient checking of your set up thanks to timestamped function recording.

Along side amplified electrical performances, ATyS p provide a large standard of protection throughout the complete set up lifecycle.

Probability to set periodic genset startup Chance to set periodic genset startup ATyS p switches give supplemental features for upkeep. They consist of a programmable genset beginning functionality which will allow the starting off dates and working occasions to be configured.

Electrical power backup The built-in Power backup gives transitional electric power into the item enabling status indication (switch place, timer standing, fault notifications) and conversation to remain active without any provide present for around 30 seconds.

Guarantee an top redundancy for unexpected emergency gensets Back up the entire distribution suitable up for the crucial hundreds Market Shut

Leave a Reply